Cosa cerchi? (What are you looking for?)*

Specs

TECHNICAL DATA

Main technical data of the technologies connected to Eliwind

Inverter

Inverter MIT Eliwind

Inverter product by ELPOWER Srl

MAIN SPECIFICATIONS INVERTER

  • Digital conversion system with ELPOWER Srl Control
  • Rated power 60kW
  • Output voltage 400V, 50Hz frequency , output side
  • Overload 110% for 1 min \ 5 min
  • THDI <5% -cosfi 0.99
  • Performance generator side of the stadium:
  • Input voltage max 480V AC
  • Input frequency max 100Hz
  • Output voltage 700Vcc
  • Rated power 60kW
  • Overload 110% for 1 min \ 5 min Digital -control
  • THDI <5% -cosfi 0.99
  • Auxiliary N07VK Power cables (<1mm2) type RADOX155
  • Ambient temperature -10 ° C + 40 ° C (50 ° C internal framework)
  • Degree of protection IP30 -cavi used CEI 20-22
  • Dimensions H1950 L1400 P600-color RAL 7035
  • CEI 0-21 Standard Certifications -CE EN 61000-6-1-2-3-11-12

Generator

Turbina MIT Eliwind

Generator EV560M product by SOGA SpA

MAIN TECHNICAL DATA GENERATOR

  • Synchronous generator radial flux permanent magnet SOGA SpA
  • EV560M -70RPM
  • Voltage 400V 50Hz frequency
  • Current 117AMPS
  • Degree of protection IP64
  • Ambient temperature -25 ° C + 45 ° C
  • Certification Soga SpA ISO 9001 -standard-B.V.C.n.229580 IEC 60034-1